Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Int J Mol Sci ; 24(9)2023 May 02.
Article in English | MEDLINE | ID: covidwho-2313810

ABSTRACT

SARS-CoV-2, the causative agent of COVID-19, has spread around the world with more than 700 million cases and 6.8 million deaths. Various variants of concern (VoC) have emerged due to mutations and recombination and concurrent selection for increased viral fitness and immune evasion. The viral protein that primarily determines the pathogenicity, infectivity, and transmissibility is the Spike protein. To analyze the specific impact of variant Spike proteins on infection dynamics, we constructed SARS-CoV-2 with a uniform B.1 backbone but with alternative Spike proteins. In addition, ORF6 was replaced by EYFP as a biological safety measure, and for use of this well-established reporter. We show that namely the delta variant Spike proteins cause a distinct phenotype from the wild type (B.1, D614G) and other variants of concern. Furthermore, we demonstrate that the omicron BA.1 Spike results in lower viral loads and a less efficient spread in vitro. Finally, we utilized viruses with the two different reporters EYFP and mCherry to establish a competitive growth assay, demonstrating that most but not all Spike variant viruses were able to outcompete wild type SARS-CoV-2 B.1.


Subject(s)
COVID-19 , Humans , Mutation , SARS-CoV-2/genetics , Spike Glycoprotein, Coronavirus/genetics
2.
Infection ; 2023 Apr 17.
Article in English | MEDLINE | ID: covidwho-2303264

ABSTRACT

PURPOSE: The Ad26.COV2.S vaccine is a replication-incompetent human adenovirus type 26 vector encoding the SARS-CoV-2 spike protein. In a phase 1-2a trial, a single dose of Ad26.COV2.S induced SARS-CoV-2 spike-specific antibodies in ≥ 96% of healthy adults. To investigate vaccine immunogenicity in HIV-1-infection, we measured SARS-CoV-2 spike-specific antibodies in Ad26.COV2.S vaccinated HIV-1-infected patients and analyzed the presence of pre-existing Ad26 neutralizing antibodies. METHODS: We included all Ad26.COV2.S vaccinated HIV-1-infected patients of Erlangen HIV cohort fulfilling all inclusion criteria. The study cohort consisted of 15 HIV-1-infected patients and three HIV-1-uninfected subjects who received the Ad26.COV2.S vaccine between April and November 2021. Pre-vaccination sera were collected between October 2014 and June 2021, post-vaccination sera between June and December 2021. Neutralizing antibodies towards Ad26 were determined by a FACS-based inhibition assay measuring the expression of SARS-CoV-2 spike and adenoviral proteins in HEK293T cells after in-vitro transduction with Ad26.COV2.S or the control ChAdOx1-S. RESULTS: Six out of 15 HIV-1-infected patients failed to develop SARS-CoV-2-specific antibodies and four patients developed weak antibody responses after vaccination with Ad26.COV2.S. Pre-vaccination sera of four of the six vaccine non-responders showed neutralizing activity towards Ad26.COV2.S but not toward the ChAdOx1-S vaccine at 1:50 dilution. After Ad26.COV2.S vaccination, 17 of the 18 subjects developed strong Ad26-neutralizing activity and only one of the 18 subjects showed neutralizing activity towards the ChAdOx1-S vaccine. CONCLUSION: Ad26.COV2.S vaccination showed a high failure rate in HIV-1-infected patients. Pre-existing immunity against Ad26 could be an important contributor to poor vaccine efficacy in a subgroup of patients.

3.
GMS hygiene and infection control ; 17, 2022.
Article in English | EuropePMC | ID: covidwho-2167721

ABSTRACT

As an important element in the regional containment of the COVID-19 pandemic a PCR testing laboratory with a cooperative character was founded in spring 2021 to screen for SARS-CoV-2 in the Nuremberg region, Germany. The aim was to detect asymptomatic infections in day care facilities for children, schools, and companies. The laboratory used an established RT-PCR protocol and analyzed approximately 18,500 pools of up to 25 pooled samples each from gargles or swabs ("lollipops”) from up to 135 facilities between July 2021 and June 2022. Usually, the participating facilities were informed about positive pools within a few hours. Retention samples from positive pools were usually analyzed on the same day, and the results were reported to the facilities as well as the German Electronic Reporting and Information System (DEMIS). In the laboratory results, both the local incidences and the transition from the Delta- to the Omicron surge in early 2022 were well reflected. It is plausible that about 4,800 secondary infections could be prevented from the approximately 1,570 positive individual samples detected in conjunction with appropriate isolation measures. Such a PCR laboratory, which is characterized by short response times and high flexibility, can thus provide valuable services for regional surveillance of infection incidence.

4.
GMS Hyg Infect Control ; 17: Doc22, 2022.
Article in English | MEDLINE | ID: covidwho-2162924

ABSTRACT

As an important element in the regional containment of the COVID-19 pandemic a PCR testing laboratory with a cooperative character was founded in spring 2021 to screen for SARS-CoV-2 in the Nuremberg region, Germany. The aim was to detect asymptomatic infections in day care facilities for children, schools, and companies. The laboratory used an established RT-PCR protocol and analyzed approximately 18,500 pools of up to 25 pooled samples each from gargles or swabs ("lollipops") from up to 135 facilities between July 2021 and June 2022. Usually, the participating facilities were informed about positive pools within a few hours. Retention samples from positive pools were usually analyzed on the same day, and the results were reported to the facilities as well as the German Electronic Reporting and Information System (DEMIS). In the laboratory results, both the local incidences and the transition from the Delta- to the Omicron surge in early 2022 were well reflected. It is plausible that about 4,800 secondary infections could be prevented from the approximately 1,570 positive individual samples detected in conjunction with appropriate isolation measures. Such a PCR laboratory, which is characterized by short response times and high flexibility, can thus provide valuable services for regional surveillance of infection incidence.

5.
Viruses ; 14(6)2022 05 27.
Article in English | MEDLINE | ID: covidwho-1869821

ABSTRACT

Herein, we provide results from a prospective population-based longitudinal follow-up (FU) SARS-CoV-2 serosurveillance study in Tirschenreuth, the county which was hit hardest in Germany in spring 2020 and early 2021. Of 4203 individuals aged 14 years or older enrolled at baseline (BL, June 2020), 3546 participated at FU1 (November 2020) and 3391 at FU2 (April 2021). Key metrics comprising standardized seroprevalence, surveillance detection ratio (SDR), infection fatality ratio (IFR) and success of the vaccination campaign were derived using the Roche N- and S-Elecsys anti-SARS-CoV-2 test together with a self-administered questionnaire. N-seropositivity at BL was 9.2% (1st wave). While we observed a low new seropositivity between BL and FU1 (0.9%), the combined 2nd and 3rd wave accounted for 6.1% new N-seropositives between FU1 and FU2 (ever seropositives at FU2: 15.4%). The SDR decreased from 5.4 (BL) to 1.1 (FU2) highlighting the success of massively increased testing in the population. The IFR based on a combination of serology and registration data resulted in 3.3% between November 2020 and April 2021 compared to 2.3% until June 2020. Although IFRs were consistently higher at FU2 compared to BL across age-groups, highest among individuals aged 70+ (18.3% versus 10.7%, respectively), observed differences were within statistical uncertainty bounds. While municipalities with senior care homes showed a higher IFR at BL (3.0% with senior care home vs. 0.7% w/o), this effect diminished at FU2 (3.4% vs. 2.9%). In April 2021 (FU2), vaccination rate in the elderly was high (>77.4%, age-group 80+).


Subject(s)
COVID-19 , SARS-CoV-2 , Aged , Antibodies, Viral , COVID-19/diagnosis , COVID-19/epidemiology , Germany/epidemiology , Humans , Longitudinal Studies , Prospective Studies , Seroepidemiologic Studies
6.
Eur J Immunol ; 51(10): 2478-2484, 2021 10.
Article in English | MEDLINE | ID: covidwho-1340251

ABSTRACT

Treatment with convalescent plasma has been shown to be safe in coronavirus disease in 2019 (COVID-19) infection, although efficacy reported in immunocompetent patients varies. Nevertheless, neutralizing antibodies are a key requisite in the fight against viral infections. Patients depleted of antibody-producing B cells, such as those treated with rituximab (anti-CD20) for hematological malignancies, lack a fundamental part of their adaptive immunity. Treatment with convalescent plasma appears to be of general benefit in this particularly vulnerable cohort. We analyzed clinical course and inflammation markers of three B-cell-depleted patients suffering from COVID-19 who were treated with convalescent plasma. In addition, we measured serum antibody levels as well as peripheral blood CD38/HLA-DR-positive T-cells ex vivo and CD137-positive T-cells after in vitro stimulation with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-derived peptides in these patients. We observed that therapy with convalescent plasma was effective in all three patients and analysis of CD137-positive T-cells after stimulation with SARS-CoV-2 peptides showed an increase in peptide-specific T-cells after application of convalescent plasma. In conclusion, we here demonstrate efficacy of convalescent plasma therapy in three B-cell-depleted patients and present data that suggest that while application of convalescent plasma elevates systemic antibody levels only transiently, it may also boost specific T-cell responses.


Subject(s)
Antibodies, Viral/blood , B-Lymphocytes/immunology , COVID-19/therapy , T-Lymphocytes/immunology , Adolescent , Aged , Antibodies, Neutralizing/blood , B-Lymphocytes/cytology , Humans , Immunity, Cellular/immunology , Immunization, Passive/methods , Lymphocyte Count , Lymphocyte Depletion , Lymphoma, B-Cell/drug therapy , Lymphoma, Mantle-Cell/drug therapy , Male , Middle Aged , Precursor Cell Lymphoblastic Leukemia-Lymphoma/drug therapy , Rituximab/adverse effects , SARS-CoV-2/immunology , Treatment Outcome , Tumor Necrosis Factor Receptor Superfamily, Member 9/metabolism , COVID-19 Serotherapy
8.
Eur J Clin Microbiol Infect Dis ; 40(9): 1983-1997, 2021 Sep.
Article in English | MEDLINE | ID: covidwho-1263157

ABSTRACT

SARS-CoV-2 antibody assays are used for epidemiological studies and for the assessment of vaccine responses in highly vulnerable patients. So far, data on cross-reactivity of SARS-CoV-2 antibody assays is limited. Here, we compared four enzyme-linked immunosorbent assays (ELISAs; Vircell SARS-CoV-2 IgM/IgA and IgG, Euroimmun SARS-CoV-2 IgA and IgG) for detection of anti-SARS-CoV-2 antibodies in 207 patients with COVID-19, 178 patients with serological evidence of different bacterial infections, 107 patients with confirmed viral respiratory disease, and 80 controls from the pre-COVID-19 era. In COVID-19 patients, the assays showed highest sensitivity in week 3 (Vircell-IgM/A and Euroimmun-IgA: 78.9% each) and after week 7 (Vircell-IgG: 97.9%; Euroimmun-IgG: 92.1%). The antibody indices were higher in patients with fatal disease. In general, IgM/IgA assays had only limited or no benefit over IgG assays. In patients with non-SARS-CoV-2 respiratory infections, IgG assays were more specific than IgM/IgA assays, and bacterial infections were associated with more false-positive results than viral infections. The specificities in bacterial and viral infections were 68.0 and 81.3% (Vircell-IgM/IgA), 84.8 and 96.3% (Euroimmun-IgA), 97.8 and 86.0% (Vircell-IgG), and 97.8 and 99.1% (Euroimmun-IgG), respectively. Sera from patients positive for antibodies against Mycoplasma pneumoniae, Chlamydia psittaci, and Legionella pneumophila yielded particularly high rates of unspecific false-positive results in the IgM/IgA assays, which was revealed by applying a highly specific flow-cytometric assay using HEK 293 T cells expressing the SARS-CoV-2 spike protein. Positive results obtained with anti-SARS-CoV-2 IgM/IgA ELISAs require careful interpretation, especially if there is evidence for prior bacterial respiratory infections.


Subject(s)
Antibodies, Viral/blood , Bacterial Infections/diagnosis , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Respiratory Tract Infections/diagnosis , Antibodies, Bacterial/blood , Bacterial Infections/blood , COVID-19/blood , COVID-19/virology , Enzyme-Linked Immunosorbent Assay , Humans , Immunoglobulin A/blood , Immunoglobulin G/blood , Immunoglobulin M/blood , Respiratory Tract Infections/blood , SARS-CoV-2/immunology , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus/immunology
9.
Viruses ; 13(6)2021 06 10.
Article in English | MEDLINE | ID: covidwho-1264531

ABSTRACT

SARS-CoV-2 infection fatality ratios (IFR) remain controversially discussed with implications for political measures. The German county of Tirschenreuth suffered a severe SARS-CoV-2 outbreak in spring 2020, with particularly high case fatality ratio (CFR). To estimate seroprevalence, underreported infections, and IFR for the Tirschenreuth population aged ≥14 years in June/July 2020, we conducted a population-based study including home visits for the elderly, and analyzed 4203 participants for SARS-CoV-2 antibodies via three antibody tests. Latent class analysis yielded 8.6% standardized county-wide seroprevalence, a factor of underreported infections of 5.0, and 2.5% overall IFR. Seroprevalence was two-fold higher among medical workers and one third among current smokers with similar proportions of registered infections. While seroprevalence did not show an age-trend, the factor of underreported infections was 12.2 in the young versus 1.7 for ≥85-year-old. Age-specific IFRs were <0.5% below 60 years of age, 1.0% for age 60-69, and 13.2% for age 70+. Senior care homes accounted for 45% of COVID-19-related deaths, reflected by an IFR of 7.5% among individuals aged 70+ and an overall IFR of 1.4% when excluding senior care home residents from our computation. Our data underscore senior care home infections as key determinant of IFR additionally to age, insufficient targeted testing in the young, and the need for further investigations on behavioral or molecular causes of the fewer infections among current smokers.


Subject(s)
Antibodies, Viral/blood , COVID-19/epidemiology , COVID-19/mortality , Population Surveillance/methods , SARS-CoV-2/immunology , Adolescent , Adult , Aged , Aged, 80 and over , COVID-19/blood , COVID-19/immunology , Female , Germany/epidemiology , Humans , Latent Class Analysis , Male , Middle Aged , Prospective Studies , Seasons , Seroepidemiologic Studies , Surveys and Questionnaires , Young Adult
10.
Clin Microbiol Infect ; 27(9): 1353.e1-1353.e5, 2021 Sep.
Article in English | MEDLINE | ID: covidwho-1240261

ABSTRACT

OBJECTIVES: Detection and surveillance of SARS-CoV-2 is of eminent importance, particularly due to the rapid emergence of variants of concern (VOCs). In this study we evaluated if a commercially available quantitative real-time PCR (qRT-PCR) assay can identify SARS-CoV-2 B.1.1.7 lineage samples by a specific N gene dropout or Ct value shift compared with the S or RdRp gene. METHODS: VOC B.1.1.7 and non-B.1.1.7 SARS-CoV-2-positive patient samples were identified via whole-genome sequencing and variant-specific PCR. Confirmed B.1.1.7 (n = 48) and non-B.1.1.7 samples (n = 58) were analysed using the Allplex™ SARS-CoV-2/FluA/FluB/RSV™ PCR assay for presence of SARS-CoV-2 S, RdRp and N genes. The N gene coding sequence of SARS-CoV-2 with and without the D3L mutation (specific for B.1.1.7) was cloned into pCR™II-TOPO™ vectors to validate polymorphism-dependent N gene dropout with the Allplex™ SARS-CoV-2/FluA/FluB/RSV™ PCR assay. RESULTS: All studied B.1.1.7-positive patient samples showed significantly higher Ct values in qRT-PCR (Δ6-10, N gene dropout on Ct values > 29) of N gene than the corresponding values of S (p ≤ 0.0001) and RdRp (p ≤ 0.0001) genes. The assay reliably discriminated B.1.1.7 and non-B.1.1.7 positive samples (area under the curve = 1) in a receiver operating characteristic curve analysis. Identical Ct value shifts (Δ7-10) were detected in reverse genetic experiments, using isolated plasmids containing N gene coding sequences corresponding to D3 or 3L variants. DISCUSSION: An N gene dropout or Ct value shift is shown for B.1.1.7-positive samples in the Allplex™ SARS-CoV-2/FluA/FluB/RSV™ PCR assay. This approach can be used as a rapid tool for B.1.1.7 detection in single assay high throughput diagnostics.


Subject(s)
COVID-19/diagnosis , Coronavirus Nucleocapsid Proteins/genetics , SARS-CoV-2/classification , Whole Genome Sequencing/methods , COVID-19 Nucleic Acid Testing , Genome, Viral , High-Throughput Nucleotide Sequencing , Humans , Multiplex Polymerase Chain Reaction , Mutation , ROC Curve , SARS-CoV-2/genetics , Sensitivity and Specificity
12.
Transfusion ; 61(2): 368-374, 2021 02.
Article in English | MEDLINE | ID: covidwho-894804

ABSTRACT

BACKGROUND: The frequency of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNAemia in blood donors is uncertain. Thus, assays for SARS-CoV-2 RNA detection in blood, validated on commercially available polymerase chain reaction (PCR) systems, are required to allow a good comparability of data. STUDY DESIGN AND METHODS: The cobas SARS-CoV-2 dual-target reverse transcriptase PCR (RT-PCR) assay, licensed for respiratory swab SARS-CoV-2 RNA testing, was validated for detection of viral RNA in blood. For the validation panel, SARS-CoV-2-positive plasma samples were prepared by spiking SARS-CoV-2-positive respiratory specimens in negative human plasma. The 95% limit of detection (LOD95) was determined by probit analysis. For clinical validation, coronavirus disease 2019 (COVID-19) convalescent plasma (CCP) donors and patients with COVID-19 with a severe disease course treated in an intensive care unit (ICU) were included. RESULTS: The validation of the SARS-CoV-2 RT-PCR assay for blood demonstrated high sensitivity and specificity and intra- and inter-assay precision and efficiency. The LOD95 for SARS-CoV-2 RNA was 5.0 genome copies/mL (95% confidence interval [CI], 3.3-12 copies/mL) for target 1 and 4.3 genome copies/mL (95% CI, 2.9-10 copies/mL) for target 2. In a cohort of 39 CCP donors with 66 CCP donations no SARS-CoV-2 RNA in plasma was detected. Screening of 25 blood samples of 19 ICU patients with COVID-19 showed six positive results for SARS-CoV-2 RNA in at least one target of the assay. CONCLUSION: The SARS-CoV-2 RNA assay, only licensed for respiratory swabs, performed on a PCR system for high-throughput testing, showed a good assay performance for blood testing.


Subject(s)
COVID-19/diagnosis , COVID-19/therapy , SARS-CoV-2/pathogenicity , Aged , Aged, 80 and over , Blood Donors , Female , Humans , Immunization, Passive , Male , Middle Aged , RNA, Viral/genetics , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/genetics , COVID-19 Serotherapy
13.
Eur J Clin Microbiol Infect Dis ; 40(4): 751-759, 2021 Apr.
Article in English | MEDLINE | ID: covidwho-880323

ABSTRACT

SARS-CoV-2 has emerged as a previously unknown zoonotic coronavirus that spread worldwide causing a serious pandemic. While reliable nucleic acid-based diagnostic assays were rapidly available, only a limited number of validated serological assays were available in the early phase of the pandemic. Here, we evaluated a novel flow cytometric approach to assess spike-specific antibody responses.HEK 293T cells expressing SARS-CoV-2 spike protein in its natural confirmation on the surface were used to detect specific IgG and IgM antibody responses in patient sera by flow cytometry. A soluble angiotensin-converting-enzyme 2 (ACE-2) variant was developed as external standard to quantify spike-specific antibody responses on different assay platforms. Analyses of 201 pre-COVID-19 sera proved a high assay specificity in comparison to commercially available CLIA and ELISA systems, while also revealing the highest sensitivity in specimens from PCR-confirmed SARS-CoV-2-infected patients. The external standard allowed robust quantification of antibody responses among different assay platforms. In conclusion, our newly established flow cytometric assay allows sensitive and quantitative detection of SARS-CoV-2-specific antibodies, which can be easily adopted in different laboratories and does not rely on external supply of assay kits. The flow cytometric assay also provides a blueprint for rapid development of serological tests to other emerging viral infections.


Subject(s)
Antibodies, Viral/immunology , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Immunoglobulin G/immunology , Immunoglobulin M/immunology , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/immunology , Angiotensin-Converting Enzyme 2 , Enzyme-Linked Immunosorbent Assay , Flow Cytometry/methods , HEK293 Cells , Humans , Reference Standards , Reproducibility of Results , Sensitivity and Specificity
14.
Euro Surveill ; 25(39)2020 10.
Article in English | MEDLINE | ID: covidwho-808986

ABSTRACT

We found that a single nucleotide polymorphism (SNP) in the nucleoprotein gene of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from a patient interfered with detection in a widely used commercial assay. Some 0.2% of the isolates in the EpiCoV database contain this SNP. Although SARS-CoV-2 was still detected by the other probe in the assay, this underlines the necessity of targeting two independent essential regions of a pathogen for reliable detection.


Subject(s)
Betacoronavirus/genetics , Clinical Laboratory Techniques , Coronavirus Infections/diagnosis , Nucleoproteins/genetics , Pandemics , Pneumonia, Viral/diagnosis , Point Mutation , Polymorphism, Single Nucleotide , RNA, Viral/genetics , Real-Time Polymerase Chain Reaction , Viral Proteins/genetics , Base Sequence , Betacoronavirus/isolation & purification , COVID-19 , COVID-19 Testing , Clinical Laboratory Techniques/methods , Contact Tracing , Coronavirus Infections/virology , DNA Primers , Diagnostic Errors , False Negative Reactions , Female , Genes, Viral , Humans , Middle Aged , Nasopharynx/virology , Nucleoproteins/analysis , Phylogeny , Pneumonia, Viral/virology , Real-Time Polymerase Chain Reaction/methods , Romania , SARS-CoV-2 , Travel-Related Illness , Viral Proteins/analysis
SELECTION OF CITATIONS
SEARCH DETAIL